POT-PRV-BOR-1290-APP
H.1290 - pultruded profile 50x50x5 - with blind holes (end post) - side-mounted - bottom Teflon insert included - civil works fixing not included
To comply with the standards, follow the recommendations on the drawing: I
H.1290 - pultruded profile 50x50x5 - with blind holes (end post) - side-mounted - bottom Teflon insert included - civil works fixing not included
To comply with the standards, follow the recommendations on the drawing: ID - F 0024
POT-PRV-DEB-1290-APP
H.1290 - pultruded profile 50x50x5 - with through holes (intermediate post) - side-mounted - bottom Teflon insert included - civil works fixing not included
To comply with the standards, follow the recommendations on the
H.1290 - pultruded profile 50x50x5 - with through holes (intermediate post) - side-mounted - bottom Teflon insert included - civil works fixing not included
To comply with the standards, follow the recommendations on the drawing: ID - F 0023
PMU-PRV-800-JN
L.800 - high-visibility yellow - side-mounted on a wall or guard-rail post - anchors not included
(For assembly, see technical document F 0001)
L.800 - high-visibility yellow - side-mounted on a wall or guard-rail post - anchors not included
(For assembly, see technical document F 0001)
PDE-PRV-1100-GR
H.1100 - 2 high-visibility yellow handles on a grey GRP frame - fixed on a base - 316 stainless steel bolts included - stud anchors not included
(For assembly, see technical document F 0269)
H.1100 - 2 high-visibility yellow handles on a grey GRP frame - fixed on a base - 316 stainless steel bolts included - stud anchors not included
(For assembly, see technical document F 0269)
PSE-PRV-1100-GR
H.1100 - 1 high-visibility yellow handle on a grey GRP frame - fixed on a base - 316 stainless steel bolts included - stud anchors not included
(For assembly, see technical document F 0009)
H.1100 - 1 high-visibility yellow handle on a grey GRP frame - fixed on a base - 316 stainless steel bolts included - stud anchors not included
(For assembly, see technical document F 0009)
TK-5050-6000-JAUNE
Made by pultrusion with a protective surface veil.
70% glass fibre, 30% isophthalic polyester resin.
Length tolerance: 0/+10/+20 mm.
Coloured right through
Sold per length
Note: the RAL shade may vary from one productio
Made by pultrusion with a protective surface veil.
70% glass fibre, 30% isophthalic polyester resin.
Length tolerance: 0/+10/+20 mm.
Coloured right through
Sold per length
Note: the RAL shade may vary from one production run to the next.
POT-PRV-PF-1300-APP
H.1300 - pultruded profile 50x50x5 - for guard-rails with flat bar rails only - fasteners for 4 flat bar rails included - fixing to the support not included
To comply with the standards, follow the recommendations on the
H.1300 - pultruded profile 50x50x5 - for guard-rails with flat bar rails only - fasteners for 4 flat bar rails included - fixing to the support not included
To comply with the standards, follow the recommendations on the drawing: ID - F 0290
EML-PEHD-25-NR
Finned HDPE plug - for kneerail with 3-5 mm wall
For installation, refer to the drawing: ID -
Finned HDPE plug - for kneerail with 3-5 mm wall
For installation, refer to the drawing: ID -
POT-PRV-BOR-1280-PAS-GR
H.1280 - pultruded profile 50x50x5 - with blind holes (end post) - mounted on U150 walkways only - bottom Teflon insert included
To comply with the standards, follow the recommendations on the drawing: ID - F 0216
H.1280 - pultruded profile 50x50x5 - with blind holes (end post) - mounted on U150 walkways only - bottom Teflon insert included
To comply with the standards, follow the recommendations on the drawing: ID - F 0216
POT-PRV-DEB-1280-PAS
H.1280 - pultruded profile 50x50x5 - with through holes (intermediate post) - mounted on U150 walkways only - bottom Teflon insert included
To comply with the standards, follow the recommendations on the drawing: ID - F
H.1280 - pultruded profile 50x50x5 - with through holes (intermediate post) - mounted on U150 walkways only - bottom Teflon insert included
To comply with the standards, follow the recommendations on the drawing: ID - F 0215
INS-PE-35x40-150-BL
Pre-drilled PE 500 35x40 L.150 - reinforcement for 50x50 GRP guard-rail post, for side-mounted installation
For installation, refer to the drawing: ID -
Pre-drilled PE 500 35x40 L.150 - reinforcement for 50x50 GRP guard-rail post, for side-mounted installation
For installation, refer to the drawing: ID -
RML-PRV-7047
Kneerail end fixing against a wall - GRP RAL 7047
For installation, refer to the drawing: ID -
Kneerail end fixing against a wall - GRP RAL 7047
For installation, refer to the drawing: ID -
RMM-PRV-7047
Ergonomic handrail end fixing against a wall - GRP
For installation, refer to the drawing: ID -
Ergonomic handrail end fixing against a wall - GRP
For installation, refer to the drawing: ID -
PRT-PRV-725-7047-APP
H.1100 - clear width 725 - side-mounted - pultruded grey GRP RAL 7047 - ISO 14122-3 / NF E85-015 - 2 self-closing hinges + 1 composite stop
To comply with the standards, follow the recommendations on the drawing: ID - F
H.1100 - clear width 725 - side-mounted - pultruded grey GRP RAL 7047 - ISO 14122-3 / NF E85-015 - 2 self-closing hinges + 1 composite stop
To comply with the standards, follow the recommendations on the drawing: ID - F 0319
EMB-PRV-PRO-3T-7047
For 50x50 square post only - 3 M13 fixings - 316L stainless steel adjusting screws for levelling - grey GRP RAL 7047
For installation, refer to the drawing: ID - ST
For 50x50 square post only - 3 M13 fixings - 316L stainless steel adjusting screws for levelling - grey GRP RAL 7047
For installation, refer to the drawing: ID - ST
PORT-PRV-725-7047-PAS
H.1100 - clear width 725 - walkway-mounted only - pultruded grey GRP RAL 7047 - ISO 14122-3 / NF E85-015 - 2 self-closing hinges + 1 stainless steel stop + 2 posts on bases with Delrin insert
To comply with the standards
H.1100 - clear width 725 - walkway-mounted only - pultruded grey GRP RAL 7047 - ISO 14122-3 / NF E85-015 - 2 self-closing hinges + 1 stainless steel stop + 2 posts on bases with Delrin insert
To comply with the standards, follow the recommendations on the drawing: ID - F 0315