Coastal sites and wet environments
Sea spray, chlorine, ozone and H₂S don’t corrode composite.
A fall protection grid has one job: to stop a fall on the day the hatch or chamber is open. The idréva bars, in GRP (glass-reinforced plastic) composite, have been validated by a 1,200 J impact test, for T1 hatches and civil works installation alike.
As soon as a hatch or chamber is opened for work, the structure becomes a drop of several metres. Collective protection comes before personal protective equipment.
Wastewater treatment plant, valve chamber, reservoir: the grid stays in place under the T1 hatch and drops back down after each entry.
Grids for T1 hatchesNon-standard structures: the module can be cut to size on site and combined with others to cover the full width of the opening.
Civil works gridsSea spray, chlorine, ozone and H₂S don’t corrode composite.
3 consecutive impacts following the INRS ED 6076 method: the bag does not pass through. Validated by a third-party inspection body.
H₂S, chlorine, ozone and saline atmospheres don’t attack composite.
The grid drops back into the closed position by itself: nobody has to close it.


Under a T1 hatch → grid for hatches · non-standard chamber or shaft → civil works module. The numbers come from the catalogue and are updated continuously.

600 × 600 · 800 × 800 · 1,000 × 1,000 · 1,500 × 800 mm. Each size is compatible only with the T1-Std hatch of the same size.
4 productsView T1 hatches →
2 L.1200 bars to cut to size on site, 200 mm spacing, independent opening, self-closing, stainless steel comb, 2 GRP angles.
1 productThe hatch and its grid are chosen together: same size, built-in bars.
The Hatches rangeWhat the test measures, then the documents in the pro portal.
The bag does not pass through the grid. Validated by a third-party inspection body.
Onto the grid resting on its frame, or about 1,177 J.
idréva documents are reserved for professional accounts. Request access Sign in
No configurator for grids: you add the right-size grid, or the civil works modules, to your estimate.
Grid for a T1 hatch or civil works modules: you add them to your estimate, in your portal.
In the pro portalThe design office checks every request. Your account manager sends you the updated quote.
Quote within 48 working hoursMade to order in Normandy, delivered ready to install.
Made in NormandyAccess is approved within 24 working hours. There’s no obligation.
Seven short answers. For anything else, your account manager replies in the pro portal.
With a 1,200 J impact test, following the INRS ED 6076 method, Annex 5: a 50 kg bag dropped from 2.40 m onto the grid resting on its frame. The bars were validated by a third-party inspection body after 3 consecutive impacts, without the bag passing through them.
Grids for hatches come in 4 sizes: 600 × 600, 800 × 800, 1,000 × 1,000 and 1,500 × 800 mm. Each one is compatible only with the T1-Std hatch of the same size.
With the civil works module: 2 L.1200 bars to cut to size on site, spaced 200 mm apart, mounted on GRP angles. The modules combine to cover the full width of the opening.
Just one. Once opened, the grid drops back automatically into the closed position; the stainless steel comb handles locking and alignment.
Yes. Composite is chemically inert to H₂S, chlorine, ozone and saline atmospheres: in wastewater treatment plants, valve chambers or coastal sites.
So they can be seen. The GRP bars are yellow, coloured right through: the colour doesn’t flake off.
No. Prices, data sheets, drawings and estimates are reserved for the workwith. pro portal, open to operators, distributors and installers. Access is free, with no obligation, and approved within 24 working hours.